Home Doors Entrance Doors Fire-Rated Doors Acoustic Doors Sliding Doors Folding Doors Pivot Doors Concealed / Invisible Doors Security Doors Interior Doors Commercial Laminate Doors Cast Aluminum Doors Wall Finishes Cabinetry & Wardrobes Wardrobes & Fitted Robes Walk-in Dressing Rooms Kitchen & Bar Casework Vanities & Washroom Minibar & Pantry Media, Display & Feature Hospitality The Milano Finish Open-pore & super-matte The wood palette Finish categories Request a sample box Capabilities Full capability matrix Marquetry & Inlay Forming & Curves CNC Carving & Screens Oversized — to 8 m 3D Relief & Texture Invisible & Concealed Doors Multi-material Integration Gold Leaf & Gilding Selected Interiors Insights Contact
KENT fire-rated door in a hotel corridor
Doors · Fire-Rated Doors

Fire-rated doors, tested as a complete doorset

30 to 120 minutes of certified protection — to UL, EN, BS and GB standards.
Overview

A fire rating belongs to the whole assembly — leaf, frame, glazing, seals and hardware tested together.

KENT builds fire doors as a certified doorset rated 30, 45, 60, 90 or 120 minutes against UL 10C, EN 1634, BS 476 and GB 12955. A certified fire-resistant core carries the rating; intumescent and smoke seals close the gaps under heat; certified closers, hinges and fire-rated vision glazing complete the set; and the same leaf can be specified acoustic to 45 dB Rw. Single or double, oversized within the tested limits, and finished across the full KENT range — so a life-safety door still matches the architecture.

Edge of a fire door showing intumescent and smoke seals
01

The rating lives in the whole doorset

A heavy core alone does not hold a rating. KENT tests and supplies the complete assembly — core, intumescent and smoke seals, closer, hinges and any vision panel — so the certificate matches what is installed.

Rating30 · 45 · 60 · 90 · 120 minutes
StandardsUL 10C · EN 1634 · BS 476 · GB 12955
Smoke controlOptional Sa / S200 smoke seals
AcousticCombinable, up to 45 dB Rw
Fire-rated door with a certified vision panel and veneer face
02

Certified, and still beautiful

A fire door does not have to look like one. The certified core takes the full KENT face range — veneer, laminate or steel — with certified fire-rated glazing where a vision panel is required.

CoreCertified fire-resistant core
Vision panelsCertified fire-rated glazing
HardwareCertified closers, hinges, intumescent & smoke seals
Face & finishFull KENT range — veneer, laminate or steel
Configurations

Fire-rated configurations

From a 30-minute office leaf to a 120-minute double — single or double, with or without a certified vision panel.

Specification

Fire-rated door — specification

Fire rating30 · 45 · 60 · 90 · 120 minutes
StandardsUL 10C · EN 1634 · BS 476 · GB 12955
Smoke controlOptional Sa / S200 smoke seals
Acoustic optionCombinable, up to 45 dB Rw
Leaf & operationSingle & double; oversized within tested limits
HardwareCertified closers, hinges, intumescent & smoke seals
Tested assembly[ certificate refs supplied per project ]
FAQ

Questions specifiers ask

Does the rating apply to the leaf or the whole door?+
To the complete tested assembly — leaf, frame, seals, glazing and hardware. KENT supplies certificates for authority (AHJ) approval.
Can a fire door also be acoustic?+
Yes — one certified doorset can carry both ratings, up to 45 dB Rw.
Which standard should we specify?+
It depends on the jurisdiction and the project's code basis. KENT tests to UL 10C, EN 1634, BS 476 and GB 12955; see the fire-ratings guide to compare.
Can it be oversized?+
Within the tested limits for the rating, yes — oversized single and double leaves are available.
Fire and acoustic ratings apply to the complete tested assembly; certificates are supplied for AHJ approval. Images are indicative until project photography is supplied.